Accident Boeing 717-2BD N955AT,
ASN logo
 

Date:Wednesday 28 June 2023
Time:08:58
Type:Silhouette image of generic B712 model; specific model in this crash may look slightly different    
Boeing 717-2BD
Owner/operator:Delta Air Lines
Registration: N955AT
MSN: 55017/5040
Year of manufacture:2000
Engine model:BMW RR BR715
Fatalities:Fatalities: 0 / Occupants: 104
Aircraft damage: Substantial
Category:Accident
Location:Charlotte-Douglas International Airport, NC (CLT) -   United States of America
Phase: Landing
Nature:Passenger - Scheduled
Departure airport:Atlanta Hartsfield-Jackson International Airport, GA (ATL/KATL)
Destination airport:Charlotte-Douglas International Airport, NC (CLT/KCLT)
Investigating agency: NTSB
Confidence Rating: Information verified through data from accident investigation authorities
Narrative:
Delta Air Lines flight DL1092, a Boeing 717-200, sustained substantial damage when the nose landing gear did not extend before landing at Charlotte Douglas International Airport (CLT), North Carolina. The 104 passengers and crew evacuated with no injuries.

The flight crew reported that when the airplane was about 2,000 ft above ground level (AGL), the first officer (FO) lowered the landing gear handle and observed the nose wheel unsafe condition light illuminate. The unsafe condition was confirmed in the configuration page of the electronic instrument system (EIS). A go-around was initiated to trouble shoot and complete the applicable checklists. A manual gear extension was attempted without success.

An emergency was declared with ATC and the flight proceeded inbound on the ILS 36L approach. As the airplane approached 300 ft AGL, ATC notified the flight crew that the nose wheel was not visible, and a second go-around was initiated. In an effort to lower the nose wheel, multiple normal and manual landing gear extension attempts were made to no avail and the decision was made to proceed with the landing.

The airplane touched down about 1,400 ft from the runway’s threshold and the nose was lowered onto the runway at about 80 knots. The airplane stopped just before taxiway W7 and CLT airport aircraft rescue and fire fighting (ARFF) sprayed the nose wheel area with water. The flight crew conducted the shutdown and evacuation checklists. After the fire chief verified that the area was safe, an evacuation was performed through the two forward entry doors with the passengers utilizing emergency slides.

A postaccident examination of the nose landing gear system revealed a fractured upper lock link. Due to the fractured upper lock link, the lower lock link was free to swing down to a vertical position and made contact with the nose landing gear assembly and thereby restricted its movement.

Accident investigation:
cover
  
Investigating agency: NTSB
Report number: DCA23FA339
Status: Preliminary report
Duration:
Download report: Preliminary report

Sources:


History of this aircraft

Other occurrences involving this aircraft
26 March 2003 N957AT Air Tran Airways 0 New York-La Guardia Airport, NY (LGA/KLGA) min
27 March 2003 N957AT Air Tran Airways 0 New York-La Guardia Airport, NY (LGA/KLGA) min

Location

Revision history:

Date/timeContributorUpdates

The Aviation Safety Network is an exclusive service provided by:
Quick Links:

CONNECT WITH US: FSF on social media FSF Facebook FSF Twitter FSF Youtube FSF LinkedIn FSF Instagram

©2024 Flight Safety Foundation

1920 Ballenger Av, 4th Fl.
Alexandria, Virginia 22314
www.FlightSafety.org