Serious incident Canadair CRJ-200 ,
ASN logo
ASN Wikibase Occurrence # 370137
 
This information is added by users of ASN. Neither ASN nor the Flight Safety Foundation are responsible for the completeness or correctness of this information. If you feel this information is incomplete or incorrect, you can submit corrected information.

Date:Friday 4 December 2009
Time:11:21 LT
Type:Silhouette image of generic CRJ2 model; specific model in this crash may look slightly different    
Canadair CRJ-200
Owner/operator:Pinnacle Airlines
Registration:
MSN:
Fatalities:Fatalities: 0 / Occupants: 52
Aircraft damage: None
Category:Serious incident
Location:Detroit-Metropolitan Wayne County Airport, MI (DTW/KDTW) -   United States of America
Phase: Take off
Nature:Passenger - Scheduled
Departure airport:Detroit-Metropolitan Wayne County Airport, MI (DTW/KDTW)
Destination airport:Wilkes-Barre/Scranton International Airport, PA (AVP/KAVP)
Investigating agency: NTSB
Confidence Rating: Accident investigation report completed and information captured
Narrative:
The Ground Control East (GCE) controller cleared Fire 2, an airport ground vehicle, to cross runway 21R at taxiway F in front of Pinnacle Airlines (FLG) flight 3720, a departing regional jet. According to crew statements, FLG3720 rotated normally and was about 150 feet above ground level when it passed the intersection of the runway and taxiway F. There was no damage to either the aircraft or the fire truck, and no reported injuries.

The Local Control East (LCE) controller cleared FLG3720 into position to hold on runway 21R at 1019:33, and was cleared for takeoff about a minute later. At 1020:29, Fire 2 contacted the GCE controller with a request, but the GCE controller could not understand the transmission and asked Fire 2 to repeat his request. Fire 2 responded, "I'm at Station 100 like [taxiway] Fox[trot] over to the [runway] 3L deice pad." The GCE controller replied, "Approved as requested." At 1021:35, Fire 2 reported clear of runway 3L. At 1021:43, GCE transmitted, "…you said the [runway] 22R deice pad." Fire 2 replied, "No, I said the [runway] 3L, sir."

DTW airport was equipped with an ASDE-X ground movement radar system that provided aircraft and vehicle tracking capabilities as well as conflict detection. According to recorded data, the system detected a conflict between Fire 2 and FLG3720 at 1021:25, just before Fire 2 entered the runway. Fire 2 completed crossing the runway and exited at taxiway F at 1021:32. FLG3720 passed taxiway F at 1021:37.

The ground controller was still in training, and was still in the process of being certified on all control positions in the tower. The day before the incident, he had been certified on the two east ground control positions by a supervisor. His certification occurred on the evening shift and took about an hour. The ground controller acknowledged that during his training he had received various comments from his instructors about scanning the airport surface, but he stated that generally they were "hit and miss" issues and did not reflect consistent deficiencies.

The supervisor said that there were no unusual conditions to help explain what had occurred. There was no construction in progress, no weather affecting the airport, no rain, and no distractions. Some aircraft had controlled departure times that needed to be assigned. However, this did not affect the operation of the time.

Since the incursion, the instructor provided some advice to the ground controller about control techniques that might help prevent him from encountering a similar problem in the future, in particular, discontinuing use of the phraseology, "proceed as requested." Issuance of specific instructions to a pilot or vehicle operator may result in a correction or other feedback from the operator. However, the instructor further noted that requiring controllers to always read back the entire request from a vehicle operator or pilot may result in lengthy, but unnecessary exchanges on the radio.

Probable Cause: The ground controller did not monitor the progress of the fire truck to ensure that the driver followed the expected route. A contributing factor was the ground controller's misunderstanding of the fire truck driver's requested destination on the airport.

Accident investigation:
cover
  
Investigating agency: NTSB
Report number: OPS10IA003
Status: Investigation completed
Duration: 6 months
Download report: Final report

Sources:

NTSB OPS10IA003

Location

Revision history:

Date/timeContributorUpdates
25-Mar-2024 07:31 ASN Update Bot Added
25-Mar-2024 08:00 ASN Updated [Aircraft type, Operator, Location, Nature, Narrative]

Corrections or additions? ... Edit this accident description