ASN Wikibase Occurrence # 346142
This information is added by users of ASN. Neither ASN nor the Flight Safety Foundation are responsible for the completeness or correctness of this information.
If you feel this information is incomplete or incorrect, you can
submit corrected information.
Date: | Wednesday 18 August 2021 |
Time: | |
Type: | Avro RJ85 |
Owner/operator: | TezJet |
Registration: | EX-27003 |
MSN: | E.2296 |
Fatalities: | Fatalities: 0 / Occupants: 75 |
Aircraft damage: | None |
Category: | Incident |
Location: | near Osh -
Kyrgyzstan
|
Phase: | En route |
Nature: | Passenger - Scheduled |
Departure airport: | Osh Airport (OSS/UCFO) |
Destination airport: | Bishkek-Manas International Airport (FRU/UCFM) |
Confidence Rating: | Accident investigation report completed and information captured |
Narrative:TezJet flight TEZ128, an Avro RJ85, suffered a cabin presurization issued after departure from Osh. The aircraft returned to Osh.
Conclusion: Failure of the automatic boost control system along the exhaust valve No. 2 which was stuck open.
The air pressure control system in the passenger cabin could not maintain the set pressure as too much air flow went through the open exhaust valve No. 2.
Accident investigation:
|
| |
Investigating agency: | |
Report number: | |
Status: | Investigation completed |
Duration: | |
Download report: | Final report |
|
Sources:
Kyrgyz CAA
Revision history:
Date/time | Contributor | Updates |
01-Oct-2023 10:30 |
harro |
Added |
The Aviation Safety Network is an exclusive service provided by: