ASN Wikibase Occurrence # 36378
This information is added by users of ASN. Neither ASN nor the Flight Safety Foundation are responsible for the completeness or correctness of this information.
If you feel this information is incomplete or incorrect, you can
submit corrected information.
Date: | Saturday 10 December 1994 |
Time: | 18:58 |
Type: | Piper PA-32RT-300 |
Owner/operator: | Air Carriers |
Registration: | N6517C |
MSN: | 32R-7885030 |
Year of manufacture: | 1978 |
Total airframe hrs: | 3416 hours |
Fatalities: | Fatalities: 1 / Occupants: 1 |
Aircraft damage: | Destroyed |
Category: | Accident |
Location: | Sylvan Springs , AL -
United States of America
|
Phase: | En route |
Nature: | Unknown |
Departure airport: | Birmingham, AL (BHM) |
Destination airport: | Memphis, TN (MEM) |
Investigating agency: | NTSB |
Confidence Rating: | Accident investigation report completed and information captured |
Narrative:BEFORE DEPARTURE THE PILOT WAS ADVISED OF THE FORECAST ALTITUDE OF THE FREEZING LEVEL AND WAS ALSO ADVISED THAT THE TEMPERATURE AT THE DEPARTURE AIRPORT WAS 15 DEGREES FAHRENHEIT ABOVE FREEZING. THE FLIGHT DEPARTED AND EN ROUTE EXPERIENCED WHAT THE PILOT REPORTED AS LIGHT RIME ICING. AT THE PILOT'S REQUEST THE FLIGHT WAS CLEARED TO RETURN AND THE CONTROLLER ADVISED THE PILOT THAT AN ALTERNATE AIRPORT WITH A NON-PRECISION INSTRUMENT APPROACH PROCEDURE WAS NEARBY. THE PILOT ELECTED TO CONTINUE TO THE DEPARTURE AIRPORT ON AN ASSIGNED HEADING AND REQUESTED A LOWER ALTITUDE. THE CONTROLLER CLEARED THE FLIGHT TO CRUISE 2,500 FEET. THE AIRPLANE COLLIDED WITH AN ELECTRICAL TOWER AND 250 KV CABLE ABOUT 90 FEET ABOVE GROUND LEVEL THEN IMPACTED THE GROUND. THE TOWER WAS LOCATED ABOUT 14.3 NM AND 266 DEGREES FROM THE DEPARTURE AIRPORT. EXAMINATION OF THE AIRFRAME REVEALED NO EVIDENCE OF PREIMPACT FAILURE OR MALFUNCTION. EXAMINATION OF THE ENGINE REVEALED NO EVIDENCE OF PREIMPACT FAILURE OR MALFUNCTION. THE AIRPLANE WAS NOT CERTIFICATED FOR FLIGHT INTO ICING CONDITIONS. CAUSE: POOR IN-FLIGHT PLANNING/DECISION BY THE PILOT-IN-COMMAND FOR FAILURE TO DEVIATE TO AN ALTERNATE AIRPORT AFTER ENCOUNTERING ICING CONDITIONS IN AN AIRPLANE NOT CERTIFICATED FOR FLIGHT IN ICING CONDITIONS. ALSO, FAILURE OF THE PILOT TO MAINTAIN ALTITUDE RESULTING IN THE INFLIGHT COLLISION WITH AN ELECTRICAL TOWER.
Sources:
NTSB:
https://www.ntsb.gov/ntsb/brief.asp?ev_id=20001206X02762 Revision history:
Date/time | Contributor | Updates |
24-Oct-2008 10:30 |
ASN archive |
Added |
21-Dec-2016 19:23 |
ASN Update Bot |
Updated [Time, Damage, Category, Investigating agency] |