Serious incident Embraer ERJ-145LR N272SK,
ASN logo
ASN Wikibase Occurrence # 370234
 
This information is added by users of ASN. Neither ASN nor the Flight Safety Foundation are responsible for the completeness or correctness of this information. If you feel this information is incomplete or incorrect, you can submit corrected information.

Date:Monday 17 December 2007
Time:16:30 LT
Type:Silhouette image of generic E145 model; specific model in this crash may look slightly different    
Embraer ERJ-145LR
Owner/operator:Chautauqua Airlines
Registration: N272SK
MSN: 145306
Fatalities:Fatalities: 0 / Occupants: 53
Aircraft damage: Minor
Category:Serious incident
Location:New York-John F. Kennedy International Airport, NY (JFK) -   United States of America
Phase: Standing
Nature:Passenger - Scheduled
Departure airport:New York-John F. Kennedy International Airport, NY (JFK)
Destination airport:Buffalo Niagara International Airport, NY (BUF/KBUF)
Investigating agency: NTSB
Confidence Rating: Accident investigation report completed and information captured
Narrative:
Prior to the incident flight, the Embraer EMB-145 was parked overnight with its tail pointed into the wind. During this time period, the winds were reported to be very high (on the order of 30-40 kts). The aircraft was equipped with a mechanical gust lock system designed to immobilize the forward torque tube of the elevator control system when the system is engaged. During takeoff, the flightcrew performed an emergency high-speed aborted takeoff because the captain felt a control anomaly during rotation. An inspection of the elevator control system components revealed that both left and right elevator control rods had fractured completely, rendering the elevator system inoperable. The elevator control rods fractured when the elevator surfaces repeatedly moved off the rear elevator stops due to wind gusts.

An airworthiness directive issued by the Federal Aviation Administration (AD 2005-26-15) was already in place at the time of this incident, which mandated replacement of the mechanical gust lock system on the Embraer 145 airplane with a more effective electromechanical gust lock system and required some repetitive inspections be performed until such time as the electromechanical system was installed. However, based on the findings in this incident, the FAA determined that the interim inspections mandated by AD 2005-26-15 were not adequate to detect the discrepancies exhibited in this event. As a result, the FAA subsequently issued a new airworthiness directive (AD 2008-03-03) to improve the interim inspections required until terminating action was taken by operators and also superceded AD 2005-26-15 with AD 2008-10-08 to shorten the compliance time for installation of the electromechanical gust lock system.

Probable Cause: the failure of the elevator control rods due to exposure to high winds while the aircraft was parked overnight.

Contributing to this incident was the failure of the existing airworthiness directive to adequately detect this discrepancy given the known deficiency with the mechanical gust lock design.

Accident investigation:
cover
  
Investigating agency: NTSB
Report number: DCA08IA019
Status: Investigation completed
Duration: 3 years and 6 months
Download report: Final report

Sources:

NTSB DCA08IA019

History of this aircraft

Other occurrences involving this aircraft
21 May 2021 TJ-KMM Camair-Co 0 Yaoundé-Nsimalen International Airport (NSI/FKYS) non
Runway excursion

Location

Revision history:

Date/timeContributorUpdates
25-Mar-2024 08:30 ASN Update Bot Added

Corrections or additions? ... Edit this accident description

The Aviation Safety Network is an exclusive service provided by:
Quick Links:

CONNECT WITH US: FSF on social media FSF Facebook FSF Twitter FSF Youtube FSF LinkedIn FSF Instagram

©2024 Flight Safety Foundation

1920 Ballenger Av, 4th Fl.
Alexandria, Virginia 22314
www.FlightSafety.org